シンボルマーク独立行政法人土木研究所 寒地土木研究所

論文・刊行物検索

詳細情報

発表 Physiological effects of recovery period on rainbow trout

作成年度 2011年度
論文名 Physiological effects of recovery period on rainbow trout
論文名(和訳) ニジマスの回復時間における生理学的影響
論文副題
発表会 American Fisheries Society 141st annual meeting
誌名(No./号数)
発表年月日 2011/09/04 ~ 2011/09/08
所属研究室/機関名 著者名(英名)
水環境保全チーム林田 寿文(HAYASHIDA Kazuhumi)
北海道栽培漁業振興公社新居 久也(NII Hisaya)
(有)ネットケア辻 貴敏(TSUJI Takatoshi)
北海道大学環境科学院三好 晃治(MIYOSHI Koji)
北海道大学環境科学院上田 宏(UEDA Hiroshi)
抄録
When a telemetry transmitter is attached to fish、 it is common to perform the surgery under anesthesia. The recovery period between the anesthesia/surgery and the release of fish is usually set around 24 hours. When conducting an experiment in a river、 lake or marsh、 fish are usually put in a recovery cage to watch over a weakening of fish and damage or detachment of the transmitters. However、 there have been very few studies that investigated carefully recovery period after anesthesia and surgery、 and there are many unclear points concerning the physiological effects of recovery period on fish.[*]  In this study、 rainbow trout、 Oncorhynchus mykiss、 were put in a swim chamber where they could freely swim in order to determine the time between the end of anesthesia/surgery and the recovery of their swimming ability. [*]The experiments were conducted between June and August 2010、 using a total of 28 fish of both sexes in a swim chamber under three different conditions: anesthesia only (anesthetic: FA100)、 anesthesia + surgery (making holes in the fishes’ bodies)、 and anesthesia + attachment of EMG transmitter (CEMG、 Lotek Inc.). The critical swimming speed (Ucrit) was measured five times at 6-hour intervals from 1 to 30 hours after anesthesia/surgery in order to analyze the changes in their swimming ability. The flow velocity was increased by 0.125 m/s every 15 minutes、 and the Ucrit values were calculated by measuring the time until fish got stuck into the end of the tank. In addition、 muscle activity was analyzed using EMG transmitters、 and the dissolved oxygen (DO) consumption was measured using a water quality meter. [*]  No significant difference was found between fish with EMG transmitters and the other two groups indicating that fish recovered their swimming ability within one hour after anesthesia/surgery. The average Ucrit value did not decrease during recovery period regardless of the surgery method. Although rainbow trout swam unsteadily at the time of the first Ucrit trial、 they showed efficient swimming behavior at the second and subsequent trials suggesting the possibility that they had a learning ability based on the EMG values. The measurement of DO consumption one hour after anesthesia revealed that the amount of oxygen consumed was equivalent to that in case of swimming at 0.75m/s. The results of the present study are considered to be useful to select the release time of fish to which telemetry transmitters have been attached.
このサイトで提供される情報には、PDFファイルが使われています。PDFファイルをご覧頂くにはAdobeReaderが必要です、「Get AdobeReader」をクリックしてダウンロードしてください。 AdobeReaderダウンロード
ページの先頭へ

この画面を閉じる

© 2023 Civil Engineering Research Institute for Cold Region, All rights reserved.